MOSCOW / NOVOSIBIRSK – A new technical specification for integrated ventilation, anti freeze water supply, and thermal enclosure has been released for industrial poultry operations in Russian climate zones with winter design temperatures from -25°C to -40°C. The system is documented to maintain interior microclimate parameters within ГОСТ Р 54954-2012 without electric heating redundancy for air temperature.
Maintaining litter condition and feed conversion at outdoor -35°C requires a building envelope with mean heat transfer coefficient (U-value) ≤ 0.35 W/(m²·K). The announced solution uses:
- Sandwich panels with 100 mm PIR core (density 40 kg/m³)
- Forced seal joints with butyl tape + silicone for air infiltration rate ≤ 1.5 m³/(h·m²) at 50 Pa
- Ventilation is based on heat recovery exchangers (rotary type) with verified:
- Thermal efficiency: 72–76% at -25°C outdoor / +18°C indoor
- Frost prevention cycle active when extract air drops below +5°C
In Russian poultry houses, water line freezing is the most frequent cause of uneven flock hydration in winter. The system delivers:
- Self regulating heating cable (output 15–30 W/m at 0°C, decreasing to 8–10 W/m at -40°C)
- Water temperature maintained at +8°C to +12°C at nipple drinker level
- Pipe material: 316L stainless steel (not plastic) to avoid cold cracking below -30°C
- Insulation: 19 mm closed cell elastomeric foam (thermal conductivity 0.038 W/(m·K))
Testing on a pilot farm in Kemerovo Oblast (January 2026, outdoor -37°C for 72 continuous hours) showed no ice blockage, with flow rate variation ≤ 7% across 120 m of main line.
At latitude 55°N (Moscow) to 60°N (St Petersburg), natural daylight duration drops to 6–7 hours in December. The published lighting program specifies:
- 16 hours light / 8 hours dark for laying hens
- Light intensity: 5–15 lux at feed trough level (layers) / 20–30 lux for broilers
- Dawn/dusk simulation: 15 minute ramp
- Light source: 3000K LED, flicker index ≤ 0.02 to avoid stress pecking
All parameters are verified to comply with the following current norms without exemption claims:
| Parameter | Requirement | This system |
|---|---|---|
| Air ammonia concentration | ≤ 15 mg/m³ (ГОСТ Р 54954 2012) | ≤ 10 mg/m³ at max stocking |
| Floor temperature (litter) | ≥ +12°C | +14 to +17°C at -35°C outdoor |
| Water nipple flow | 70–120 mL/min | 85–110 mL/min across all tiers |
| Carbon dioxide | ≤ 2500 ppm | ≤ 2100 ppm |
The specification does not claim unlimited low temperature operation. Validated operating envelope:
- Minimum outdoor temperature: -40°C (for up to 7 consecutive days)
- Maximum wind speed at air intake: 8 m/s (with wind baffles closed)
- Electrical supply: 380V / 50 Hz, heating cable circuit with N+1 redundancy
Below -40°C, the document recommends an auxiliary air to air heater (indirect fired, propane or diesel) sized at ≥ 50 W/m² floor area.
The full technical specification (Russian and English, 47 pages) is available for engineering review. It includes:
- Heat balance calculation worksheet for any Russian region
- Wiring diagram for heating cable zones (max 60 m per circuit)
- Maintenance intervals: fan bearing grease change every 800 operating hours below -20°C
A type :
![]()
H Type:
![]()
Silverstar Offer Chicken House design service as per your raising plan .
Supply Full Auto/Semi Chikcken Farming Equipment :Steel Structure House,Feeding& drinking
and Egg Collection system, manure removal,Cooling fans etc
If u have any questions in chicken farming ,Plz feel free to contact us .Ur inquiry will be
responded asap